Qingdao Futai, Air Compressor Filter Manufacturer in China.
Place of Origin: | CHINA |
Brand Name: | QINGDAO FUTAI |
Certification: | ISO 9001:2015 |
Model Number: | 54509427 |
Type: | Oil Separator | Material: | Fiberglass |
---|---|---|---|
Product Name: | Air Oil Separator | Warranty: | 3500-5000 Hours |
Application: | Ingersoll Rand | Color: | White |
Part Number: | 54509427 | Weight: | 3-5kg |
High Light: | 54509427,Fiberglass Screw Compressor Oil Separator,6ppm Air Oil Separator |
Ingersoll Rand Screw Compressor Air Oil Separator 54509427
Ingersoll Rand oil air separator product introduction:
The compressed air flowing from the head of the air compressor will contain some air compressor oil, resulting in the deterioration of compressed air quality.
Larger oil droplets can be easily separated by centrifugal force, while smaller oil droplets (suspended oil particles) must be filtered through a micron glass fiber mesh winding layer in the oil-air separator.
54509427 oil air separator using imported materials of high pressure filter body, so that the compressor output more than 3 microns of solid particles in the air can be filtered out, are extremely small μ is about 0.01-1 m collapse of oil and gas dissolved through the filter is condensed into larger droplets, accumulated in the bottom of the filter,
Then through the siphon filter at the bottom of the depression of the return pipe to return to the lubrication system, so that the compressor discharge more pure oil-free compressed air.
Product Name: |
Air Oil Separator |
Oil Content: |
3-6ppm |
Filtration Accuracy: |
≤0.1 μm |
Max working temperature: |
120℃ |
Limited Data: |
0.5-60 m³/min |
Working pressure: |
0.7Mpa~1.0Mpa |
Recommended time: |
2000-4000h |
Material: |
Imported fiber glass from HV company |
Reasons and solutions for common failures of air compressors:
The air pressure cannot rise or rise to a certain level and then it cannot rise again.
Cause of issue:
1. Bad valve action.
2. The valve disc and valve seat are not flat and leaking.
3. Bad valve spring.
4. The valve disc is attached with dust or carbon deposits.
Troubleshooting method:
1. Grind or replace the valve.
2. Grinding or replacing the valve seat.
3. Replace the spring.
4. Clean the valve body and valve disc.
Contact Person: Wu
Tel: +8618661708013